Search Products

Pharmaceutical GMP drying oven

Outline
Steam heating, electricity, oil, electric heating steam dual four ways.
Temperature: steam heating 50-140 ℃, maximum 150 ℃;
Electrically heated 50 & mdash; 350 ℃;
HTF 150 ~ 250 ℃
Implementation of automatic temperature control, and has recorder record;
Inside walls are fully welded, are used at each transition arc transition, no dead ends.
Sealing machine, a unique rail seal, ensure the machine seal.
Inlet is equipped with high efficiency air filter; Moisture port supporting the efficiency air filter.
Double-door two-door oven achieve mechanical interlock;
Oven the parts can be assembled and disassembled quickly installed to facilitate cleaning;
The control system has text display and touch screen for your choice;
The whole in line with & ldquo; GMP & rdquo; requirements. & Nbsp;

Technical Specifications

Technical Parameters \ Model Specifications Each time the amount of drying
(Kg)
Fan power
(KW)
Steam consumption
(Kg/h)
Drying cars
(Vehicles)
Baking tray
(only)
Wide & times; deep & times; high
W×D×H(mm)
Upper and lower temperature
(℃)
GMP-0 35 0.45 8 / 16 1130×1100×1750 ±2
GMP-I 120 0.45 18 2 48 2300×1200×2000 ±2
GMP-II 240 0.9 36 4 96 2300×2200×2000 ±2
GMP-III 360 1.35 54 6 144 2430×2200×2000 ±2
GMP-IV 480 1.8 72 8 192 4460×2200×2290 ±2

【Back】